Skip to content

压缩机与空气处理

螺杆式、无油式、活塞式与工艺压缩机,以及下游的全部设备。

压缩机与空气处理

概述

Compressed air is usually the most expensive utility in a factory and the least measured. Most plants know their diesel and electricity costs to the rupee or the dirham, but very few know what a cubic metre of their own air costs to make.

Green Air supplies the whole chain, compressor, dryer, filtration, condensate treatment and the control that ties them together, and we size it from measured demand, not from a total of nameplate ratings. That is normally where the savings are found.

本系列包含

主要优势

One supplier for the whole system

Compressor, dryer, filtration and condensate specified together, so nothing is left to be matched up on site.

Measured, not estimated

Specific energy to ISO 1217 at your working pressure, and a week of logging before we size anything you are unsure about.

Parts in your country

Consumables held in Pakistan, the UAE, Saudi Arabia, Oman and Türkiye rather than shipped when you order.

Serviced by the people who sold it

The engineer who commissions the machine is the one who comes back to it.

这个板块里有什么

一切用于制造、处理或输送压缩空气的设备:螺杆式与活塞式压缩机、无油机、干燥机、过滤器、增压机、鼓风机,以及制氮设备。

多数工厂需要的不是其中一样,而是其中三样。不带干燥的压缩机会把水送进管网,而只干燥不过滤则会把油留下来。

我们把它们作为一套系统供货,因为它们本来就是这样运作的。只看一份单机样本选定设备、再把它接到现场已有的东西上——大多数压缩空气问题就是这样开始的。

  • 螺杆式、活塞式与无油压缩机
  • 冷冻式、吸附式与膜式干燥机
  • 覆盖 ISO 8573-1 各个等级的过滤
  • 用于高压工况的增压机
  • 用于低压大流量的鼓风机
  • 用您自己的空气制氮
  • 冷凝水处理至符合排放规定
  • 作为一套系统供货并调试

从哪里开始

从工况开始:空气驱动什么、每天用多少小时、它接触什么。这三个答案几乎决定了其余的一切。

如果您不知道自己的用气量,就把工具和设备告诉我们。按空气实际驱动的东西来选型,远比按一个猜出来的数字可靠。

另外,请向任何供应商索要在您的工作压力下按 ISO 1217 实测的比气耗。十年下来电费约占一台压缩机总花费的四分之三,所以这一个数字比价格决定得更多。

  • 工况、运行小时和接触对象决定规格
  • 不知道用气量时,按工具反推选型
  • 购买之前可先做实测
  • 比较的依据是按 ISO 1217 实测的比气耗
  • 在您决定之前先给出十年总成本
  • 空气品质按空气所接触的对象匹配
  • 随报价提供书面选型
  • 用小一点就够的时候,我们会如实建议

本系列的数据表

每份两页:这台机器是什么、用在哪里,以及实测数据表。内容由本站生成,因此数据表不可能说出页面上没有的话。

常见问题

How much does compressed air actually cost to produce?

Over ten years, electricity is usually 75–80% of what a compressor costs you. The purchase price is often under 15%. As a rough figure, 1 m³/min of air at 7 bar needs about 6 kW running continuously. Multiply by your tariff and your running hours and the number is normally larger than people expect.

How do I know what size compressor I need?

Not by adding up the nameplate ratings of every machine, that always oversizes. We fit data loggers for a week and size from measured demand, including how often peak load actually happens. It is common for the answer to be a smaller machine than the customer expected.

Do I need an air dryer as well as a compressor?

In Pakistan, the Gulf and most of Türkiye, yes. Warm humid air condenses inside your pipework as it cools, and that water rusts pipes, wrecks pneumatic cylinders and ruins paint finishes. A dryer is part of the installation, not an accessory.

What pressure should I run my system at?

The lowest pressure that still runs your equipment. Every extra bar costs roughly 7% more energy, permanently. Many plants supply 8.5 bar when nothing on site needs more than 6.5 at the tool.

How long should a compressor last?

A rotary screw machine maintained properly runs 40,000–60,000 hours before a major overhaul, which is fifteen years at one shift. A piston machine used within its duty cycle lasts a decade. Used continuously it often fails inside two years.

What is the difference between oil-injected and oil-free?

An oil-injected machine sprays oil into the compression chamber to seal and cool it, then separates most of it out again: leaving 1–3 mg/m³ in the air. An oil-free machine has no lubricant in the air path at all. If oil contamination would cost you a batch, you need oil-free. Otherwise oil-injected is cheaper to buy and run.

How much space does a compressor room need?

Allow one metre of clear access on the service side and enough ventilation to remove the heat, roughly 4,000 m³/h of cooling air per 30 kW installed. Under-ventilated rooms are the single most common cause of high-temperature trips in summer.

Can I run a compressor on a generator?

Yes, but size the generator for the starting current, not the running load. A star-delta start needs roughly twice the running kVA. A variable speed machine starts softly and needs far less, which often makes it the cheaper option overall on generator supply.

What maintenance does a compressor need?

Air and oil filters plus an oil sample every 2,000 hours. Separator, oil change and cooler clean every 4,000. A full performance check and motor regrease every 8,000. We publish the full task list per interval so you can compare it against any other quotation.

Can you survey our existing system before we quote?

Yes, and we prefer to. A week of logging plus a leak survey usually finds 20–30% of generated air escaping and a system running a bar or two higher than anything needs. Fixing that is cheaper than buying a machine, and we will say so.

相关产品

不确定该选哪个型号?

把您的用气量、工作压力和运行小时数发给我们。我们的工程师会完成选型并给出书面建议,不收费,也不构成任何义务。