概述
Where there is no plant room, the plant room ships with the compressor. A containerised station holds the compressor, the dryer, the filtration, the receiver, the switchgear and the ventilation inside a standard 20 or 40 foot container, wired and piped and tested before it leaves the factory.
On site it is craned into place, connected to power and to the ring main, and started. There is no building to construct, no foundation to pour and no acoustic work to commission — and when the project moves, so does the container.
主要优势
No building required
The container is the plant room. Foundations, walls, doors and acoustic treatment all leave the specification.
Tested before dispatch
The whole station is run and proven at the factory rather than assembled for the first time in a desert.
Built for the climate
Forced ventilation, dust filtration and high ambient rating specified for where it is actually going.
It moves
When the site closes the station is craned onto a truck. A plant room is not.
What goes in the container
The compressor and its air treatment, sized as one system. A receiver. The electrical panel and the incoming switchgear. Lighting, fire detection, forced ventilation sized for the heat the compressor actually rejects, and inlet filtration sized for the dust the site actually has.
Ventilation is the part that gets underestimated. A 132 kW compressor puts something close to 132 kW of heat into that box, and in a Gulf summer the difference between correctly sized ventilation and optimistic ventilation is the difference between a station that runs and one that trips every afternoon.
Where the duty demands it we build the station around two compressors with sequencing control, so a failure or a service does not stop the site.
- 20 or 40 foot container
- Compressor, dryer, filtration and receiver
- Switchgear, lighting and fire detection
- Forced ventilation sized on rejected heat
- Inlet filtration for site dust
- Single or duplex compressor arrangements
- High ambient rating as standard
- Craned into place and started the same day
技术参数
- Power range
- 22 – 700 kW
- Free air delivery
- 3.2 – 100 m³/min
- Working pressure
- 5 – 30 bar g
- Container
- 20 ft or 40 ft, oil injected or oil free, fixed speed or variable speed
- Cooling
- Air cooled or water cooled
常见问题
How long does installation take?
A day, usually. Crane it into position, connect power and the air line, commission and run. The work that would have been a building has already been done at the factory.
Can it hold two compressors?
Yes, and on any duty that cannot stop we recommend it. Two machines with sequencing control means a service or a failure does not stop the site.
What ambient temperature can it take?
We rate the ventilation for the site rather than for a standard. Tell us where it is going and what the summer peak is, and the ventilation is sized to that.
What size container is used?
20 or 40 foot, depending on the machine and what else has to go inside. The general arrangement is approved before fabrication starts.
Does it include the electrical panel?
Yes, the panel and the incoming switchgear, plus lighting and fire detection. What you connect on site is the incoming supply and the air line.
How is the dust handled?
Inlet filtration sized for the site's actual dust, not a standard figure. On a quarry or a cement plant that is the difference between an annual filter and a weekly one.
Can it be relocated?
That is much of the point. When the project moves or the site closes, the station is craned onto a truck and goes with it.
Is it noisy outside?
The container is lined and the ventilation is attenuated. Where it stands near occupied buildings we specify the low noise build and state the figure.
Does it need a foundation?
A level prepared base, not a foundation. It is a container; it is designed to sit on ground that a truck can reach.
What is serviced and how often?
The compressor and its treatment on the normal schedule, plus the ventilation filters and the fire detection check. It is one visit covering the whole station.
相关产品

四合一一体机
压缩机、干燥机、过滤器与储气罐装在一个机柜里。4 至 18 kW。
- 容积流量(FAD)
- 0.3 – 3.0 m³/min
- 工作压力
- 7 – 13 bar g
- 电机功率
- 4 – 18 kW

激光切割专用空压机
13 至 16 bar 的洁净干燥空气,按切割头而不是按厂区来定规格。
- 容积流量(FAD)
- 8.5 – 25.0 m³/min
- 工作压力
- 20 – 30 bar g
- 电机功率
- 90 – 250 kW

橇装式空压站
整套气源装在一个钢架上,管路和线路都接好,落位固定即可。
了解更多
车载式空压机
压缩机连同动力装在车辆底盘上,适合服务车队与公用事业。
- 容积流量(FAD)
- 7.1 – 13.6 m³/min
- 工作压力
- 10 – 25 bar g
- 电机功率
- 23 – 42 kW
不确定该选哪个型号?
把您的用气量、工作压力和运行小时数发给我们。我们的工程师会完成选型并给出书面建议,不收费,也不构成任何义务。