干燥机保养

Dryers fail quietly

Dryers fail quietly. A refrigerant dryer with a blocked condenser or a failed drain does not stop. It simply stops drying, and the first sign is usually water in a machine or a rejected batch, weeks later.

Our dryer service measures the actual pressure dew point being achieved rather than assuming the dryer is doing its job because the light is on.

What you get

Dew point measured

Actual achieved dew point recorded at every visit, not just a visual inspection.

Drains checked and cleared

A blocked drain is the single most common cause of water downstream.

Desiccant assessed

Bed condition checked and change scheduled before performance falls off.

Condenser cleaning

In dusty climates this is what keeps a refrigerant dryer working through summer.

合同包含什么

Condenser cleaning, drain service and a refrigerant check on a refrigerant dryer. Valve service, mufflers and a desiccant assessment on a desiccant dryer.

Every visit ends with a dew point measurement. A dryer that is running is not the same as a dryer that is drying, and only a measurement tells them apart.

It is done on the same visit as the compressor, which is the sensible arrangement and the reason most of our customers put both on one plan.

  • Condenser cleaning on refrigerant dryers
  • Valve and muffler service on desiccant dryers
  • Drain service on both
  • 每次到场都实测露点
  • Refrigerant handled to current regulation
  • Desiccant condition assessed
  • Done with the compressor service
  • Report issued the same day

The failure nobody sees

冷凝器堵塞会悄悄抬高露点。干燥机照常运转,空气照常流动,而水跑到下游的用气点,最后被人在产品里发现。

On a desiccant dryer the equivalent is a failed changeover valve. The unit sounds normal and one tower is doing all the work until the desiccant in it is exhausted.

Both are found by measuring rather than by looking, which is why the dew point reading is on every report we issue.

  • Blocked condenser raises dew point silently
  • Failed valve leaves one tower doing the work
  • Neither shows on the machine itself
  • Found by measurement, not inspection
  • Dew point on every service report
  • Alarm settings checked at each visit
  • Prefilter condition checked
  • Trend reviewed visit to visit

Parts and intervals

Interval follows the ambient and the load rather than a generic figure. A dryer in a hot plant room works far harder than the same unit in a cool one.

Desiccant lasts three to five years when the air reaching it is clean. Oil carryover kills a bed in months, which is why the prefilter is part of the service and not an extra.

Valve kits and mufflers are carried on the van, because a dryer passing air but not drying it is usually a valve and is usually fixed the same day.

  • Interval set by ambient and load
  • Desiccant every three to five years
  • Prefilter changed to protect the bed
  • Valve kits and mufflers carried on the van
  • Refrigerant top up where permitted
  • 配件本地有库存
  • 服务方案下固定价格
  • 可供应其他品牌的滤芯

常见问题

What does a refrigerant dryer need?

Condenser cleaning, drain testing and a dew point check. The condenser is the one that gets neglected, and in this climate it is the one that matters most.

How often?

Quarterly in dusty or hot locations, six-monthly in a clean plant room. Anything longer than a year is asking for a summer failure.

What does a desiccant dryer need?

Valve service, silencer replacement and a desiccant change every three to five years. Silencers block long before the desiccant is spent.

How do I know the desiccant is finished?

Dew point rises and stops recovering after a cycle. A dew point instrument tells you months before your product quality does.

Why does my dryer freeze up?

Usually a hot gas bypass valve out of adjustment, or a fan control fault. It is a control problem far more often than a refrigerant problem.

Is a dew point sensor worth fitting?

Yes, it is the only way to know the dryer is actually working, and on a desiccant machine it also allows dew point controlled purging, which saves air.

What happens if the drain fails?

Water goes downstream into your pipework, filters and tools. A failed drain undoes everything the dryer was installed to achieve.

Can we service it without stopping production?

Refrigerant dryers usually need a short shutdown. Twin-tower desiccant dryers can often be worked on one tower at a time.

How much does neglect cost?

A blocked condenser adds compressor load, raises dew point and eventually fails the refrigeration circuit. A large bill that starts as a cleaning job.

Do you keep a record?

Yes. Dew point, ambient temperature and pressure drop are logged at every visit, so you have a trend rather than a single reading.