Magnetic levitation blowers

The impeller floats on a magnetic field. 37 to 350 kW, no bearings to wear.

Technical data

Free air delivery
25.0 – 388.0 m³/min
Motor power
37 – 350 kW
Magnetic levitation blowers

Overview

A magnetic bearing holds the shaft in the air. There is no metal touching metal anywhere in the rotating assembly, which means no bearing oil, no bearing wear and no bearing replacement for the life of the machine.

It also means the shaft can turn very fast, and a blower that turns fast can drive the impeller directly with no gearbox in between. Between the gearbox that is not there and the bearings that are not there, a magnetic levitation blower typically uses twenty to thirty per cent less energy than the multi stage blower it replaces.

Key benefits

Twenty to thirty per cent less energy

No gearbox losses, no bearing losses, and a direct drive high speed motor. Measured against the roots blower it usually replaces.

No oil at all

No lubrication system, no oil changes, no oil to leak into a process or a treatment tank.

Turndown to about 45 per cent

Speed control across a wide range without the surge problems a geared machine has at low flow.

Around 80 dB(A)

Substantially quieter than a roots blower, and without its characteristic pulsation.

What is not in the machine

No gearbox. A conventional high speed blower needs one to get from motor speed to impeller speed, and it costs three to five per cent of the power plus an oil system to maintain.

No bearings in the conventional sense. Magnetic bearings hold the shaft centred using position sensors and electromagnets, correcting thousands of times a second. There is no contact, so there is nothing to wear out and nothing to lubricate.

No oil system at all, which in wastewater treatment and in food plants removes an entire contamination risk along with its maintenance. The practical result is that the routine service on these machines is an air filter and a check of the control system.

  • Direct drive, no gearbox
  • Magnetic bearings, no contact and no wear
  • No lubrication system anywhere
  • Touchdown bearings for safe coast down
  • Speed control from about 45 to 100 per cent
  • Around 80 dB(A)
  • Service is an air filter and a controls check
  • 37 to 350 kW

Reading the table

Blowers are selected on boost rather than on pressure ratio, so the table gives flow against boost in kilopascals at each installed power. One bar is a hundred kilopascals, and most aeration duties sit between 50 and 80.

Flows are given at one atmosphere and 20 °C. At the ambient temperatures and altitudes the machines actually run at, the mass flow differs, and we correct for your site conditions when we size rather than quoting the table figure.

If your duty is not on the table it is almost certainly still available. The published points are the common ones, not the limits of the range.

Model range

GA-PC-3737 kW
50 kPa
41 m³/min
70 kPa
31 m³/min
90 kPa
25 m³/min
GA-PC-4545 kW
50 kPa
50 m³/min
70 kPa
37 m³/min
90 kPa
30 m³/min
GA-PC-5555 kW
50 kPa
61 m³/min
70 kPa
46 m³/min
90 kPa
37 m³/min
GA-PC-7575 kW
50 kPa
83 m³/min
70 kPa
62 m³/min
90 kPa
51 m³/min
GA-PC-9090 kW
50 kPa
100 m³/min
70 kPa
75 m³/min
90 kPa
61 m³/min
GA-PC-110110 kW
50 kPa
122 m³/min
70 kPa
91 m³/min
90 kPa
74 m³/min
GA-PC-132132 kW
50 kPa
146 m³/min
70 kPa
110 m³/min
90 kPa
89 m³/min
GA-PC-160160 kW
50 kPa
177 m³/min
70 kPa
133 m³/min
90 kPa
108 m³/min
GA-PC-185185 kW
50 kPa
205 m³/min
70 kPa
154 m³/min
90 kPa
125 m³/min
GA-PC-200200 kW
50 kPa
222 m³/min
70 kPa
166 m³/min
90 kPa
135 m³/min
GA-PC-220220 kW
50 kPa
244 m³/min
70 kPa
183 m³/min
90 kPa
149 m³/min
GA-PC-250250 kW
50 kPa
277 m³/min
70 kPa
208 m³/min
90 kPa
169 m³/min
GA-PC-280280 kW
50 kPa
310 m³/min
70 kPa
233 m³/min
90 kPa
189 m³/min
GA-PC-300300 kW
50 kPa
333 m³/min
70 kPa
249 m³/min
90 kPa
203 m³/min
GA-PC-315315 kW
50 kPa
349 m³/min
70 kPa
261 m³/min
90 kPa
213 m³/min
GA-PC-350350 kW
50 kPa
388 m³/min
70 kPa
291 m³/min
90 kPa
237 m³/min

Performance to ISO 1217 Annex C at 20 °C inlet, 1 bar(a). Figures are typical and subject to confirmation. Ask us for the certified test report for your selected model.

Frequently asked questions

What happens in a power cut?

Touchdown bearings take the shaft as it coasts down. They are rated for a defined number of events and are a replaceable item, not a failure.

How does it compare with a roots blower?

Twenty to thirty per cent less energy, much quieter, no oil and no pulsation. It costs more to buy and repays it in a wastewater plant inside about three years.

Does it need special foundations?

No. There is almost no vibration because nothing is touching, so a level floor is sufficient.

What is the routine maintenance?

An air filter and a check of the control system. There is no gearbox, no oil and no bearing replacement interval.

How far can it turn down?

To about 45 per cent of full flow, without the surge problems a geared machine has at low flow. Speed control is continuous across that range.

How do I read the flow table?

Flow is given against boost in kilopascals at each installed power. One bar is a hundred kilopascals, and most aeration duties sit between 50 and 80.

Are the table figures what I will actually get?

They are at one atmosphere and 20 °C. At your site's temperature and altitude the mass flow differs, and we correct for that when sizing.

Is the control system complicated?

It manages the bearings thousands of times a second, but the operator interface is a screen with pressure, flow and speed. Diagnostics are logged rather than displayed constantly.

What if the bearing electronics fail?

The machine coasts down onto the touchdown bearings and stops safely. The electronics are a stocked item and replaceable without opening the rotating assembly.

Is it worth it on a small plant?

Below about 37 kW the savings are smaller and a screw blower is often the better value. We size both and show the comparison rather than defaulting to the newest technology.

Related products

Not sure which model you need?

Send us your air demand, working pressure and running hours. Our engineers will size the machine and send a written recommendation, no cost, no obligation.