Technical data

Free air delivery
0.3 – 3.0 m³/min
Working pressure
7 – 13 bar g
Motor power
4 – 18 kW
Weight
150 – 480 kg
Noise level
60 – 66 dB(A)
Four in one integrated compressors

Overview

A compressor on its own puts warm, wet, dirty air into your pipework. The dryer, the filters and the receiver are not accessories, they are the rest of the installation — and on a small site they usually end up as four separate items on the floor joined by whatever hose was available.

This range puts all four inside one cabinet, piped and wired at the factory. One item arrives, one electrical connection is made, one air outlet is piped, and the air coming out of it is already dried and filtered.

Key benefits

One connection, not four

Electrical supply in, treated air out. No interconnecting pipework to specify, buy or get wrong.

Under a square metre

The whole air system in the footprint that the compressor alone used to take.

Dried and filtered at source

The dryer is sized for the compressor it sits with, which is the commonest thing to get wrong when they are bought separately.

One service visit

Compressor, dryer and filters serviced together, on one plan, by one engineer.

Why the parts belong together

The commonest fault we are called to on a small installation is not the compressor. It is water in the ring main, and it is almost always because the dryer was chosen later, sized on the compressor's nameplate rather than on its actual outlet temperature, or left out entirely because the budget ran short.

Sizing a dryer correctly means knowing the inlet temperature and the actual flow, and both of those are known exactly when the dryer sits inside the same cabinet as the compressor. Nothing is estimated.

The receiver matters for a different reason. A small compressor with no receiver starts and stops constantly, and starting is what kills contactors and motors. A properly sized receiver turns dozens of starts an hour into a handful.

  • Compressor, dryer, filters and receiver in one cabinet
  • Dryer sized on the actual outlet temperature
  • Receiver sized to limit starts per hour
  • Drain fitted and piped from the factory
  • One electrical connection
  • One service plan covering all four

Model range

GA-B-4A-74 kW
7 bar g
0.5 m³/min
Noise level
60 dB(A)
Weight
150 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-4A-84 kW
8 bar g
0.5 m³/min
Noise level
60 dB(A)
Weight
150 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-4A-104 kW
10 bar g
0.4 m³/min
Noise level
60 dB(A)
Weight
150 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-4A-134 kW
13 bar g
0.25 m³/min
Noise level
60 dB(A)
Weight
150 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-5A-75.5 kW
7 bar g
0.8 m³/min
Noise level
60 dB(A)
Weight
170 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-5A-85.5 kW
8 bar g
0.8 m³/min
Noise level
60 dB(A)
Weight
170 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-5A-105.5 kW
10 bar g
0.63 m³/min
Noise level
60 dB(A)
Weight
170 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-5A-135.5 kW
13 bar g
0.5 m³/min
Noise level
60 dB(A)
Weight
170 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-7A-77.5 kW
7 bar g
1.15 m³/min
Noise level
62 dB(A)
Weight
190 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-7A-87.5 kW
8 bar g
1.15 m³/min
Noise level
62 dB(A)
Weight
190 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-7A-107.5 kW
10 bar g
1.0 m³/min
Noise level
62 dB(A)
Weight
190 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-7A-137.5 kW
13 bar g
0.79 m³/min
Noise level
62 dB(A)
Weight
190 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-11A-711 kW
7 bar g
1.80 m³/min
Noise level
66 dB(A)
Weight
230 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-11A-811 kW
8 bar g
1.80 m³/min
Noise level
66 dB(A)
Weight
230 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-11A-1011 kW
10 bar g
1.50 m³/min
Noise level
66 dB(A)
Weight
230 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-11A-1311 kW
13 bar g
1.20 m³/min
Noise level
66 dB(A)
Weight
230 kg
Dimensions L x W x H
800 × 620 × 810 mm
GA-B-15A-715 kW
7 bar g
2.3 m³/min
Noise level
66 dB(A)
Weight
420 kg
Dimensions L x W x H
775 × 1050 × 1050 mm
GA-B-15A-815 kW
8 bar g
2.3 m³/min
Noise level
66 dB(A)
Weight
420 kg
Dimensions L x W x H
775 × 1050 × 1050 mm
GA-B-15A-1015 kW
10 bar g
2.05 m³/min
Noise level
66 dB(A)
Weight
420 kg
Dimensions L x W x H
775 × 1050 × 1050 mm
GA-B-15A-1315 kW
13 bar g
1.65 m³/min
Noise level
66 dB(A)
Weight
420 kg
Dimensions L x W x H
775 × 1050 × 1050 mm
GA-B-18A-718 kW
7 bar g
3.0 m³/min
Noise level
66 dB(A)
Weight
480 kg
Dimensions L x W x H
775 × 1050 × 1050 mm
GA-B-18A-818 kW
8 bar g
3.0 m³/min
Noise level
66 dB(A)
Weight
480 kg
Dimensions L x W x H
775 × 1050 × 1050 mm
GA-B-18A-1018 kW
10 bar g
2.6 m³/min
Noise level
66 dB(A)
Weight
480 kg
Dimensions L x W x H
775 × 1050 × 1050 mm
GA-B-18A-1318 kW
13 bar g
2.2 m³/min
Noise level
66 dB(A)
Weight
480 kg
Dimensions L x W x H
775 × 1050 × 1050 mm

FAD measured to ISO 1217 Edition 4, Annex C and E at 1 bar a intake, 20°C, 0% humidity. Noise measured to ISO 2151 in free field conditions, tolerance ± 3 dB(A). Water-cooled versions of every model are available. Ask us for their sheet.

Frequently asked questions

Can I add a bigger receiver later?

Yes. The internal receiver limits starts; an external one adds storage for peaks. They do different jobs and adding one does not make the other redundant.

What class of air does it deliver?

With the refrigerant dryer and the standard filter set, a pressure dew point around 3 °C and ISO 8573-1 Class 1 for particulate. Higher classes are available with additional filtration.

Is it harder to service than separate items?

No, easier. Everything is reachable from the front and it is one visit rather than three separate ones on three different intervals.

How much floor space does it need?

Under a square metre on the small frames, which is the footprint the compressor alone used to take.

Why does the dryer sizing matter so much?

Because the commonest fault on a small installation is water in the ring main, and it is almost always a dryer sized on a nameplate rather than on the compressor's real outlet temperature.

Does it come with the drain fitted?

Yes, fitted and piped from the factory. A drain that was never connected is the second commonest cause of water downstream.

What supply does it need?

One electrical connection. We state the full load current and the recommended breaker size with the quotation.

Can I get it without the dryer?

You can, but on a small site we would ask why. The dryer is the part that stops water reaching your tools, and adding it later costs more than including it now.

Is it quiet enough for a workshop?

Yes, the cabinet encloses everything and the small frames run around 62 to 66 dB(A).

What is the service interval?

Air filter, oil filter, separator and oil on the compressor schedule, plus the dryer's condenser cleaned and the filter elements changed at the same visit.

Related products

Not sure which model you need?

Send us your air demand, working pressure and running hours. Our engineers will size the machine and send a written recommendation, no cost, no obligation.